Tension anchor HTA
Tension anchor, HTA
TENSANC-HTA-BASEPLT-340X60X60X3,0MM
price per selected packing unit | Individual prices for customers after login

Register now and access more than 125,000 products
The products shown are not necessarily compatible. Please always check the articles for the respective application purpose.
- Extremely high load-bearing capacities
- Compact design with small base plate for confined spaces
- Indirect mounting (max. 26 mm) via an intermediate layer (e.g. OSB)
- Extra-long back panel for optimum placement of the required number of screws/nails whilst complying with the requisite edge clearance on the wooden frame
- Sheet metal 12-µm hot-dip galvanised on both sides (S355 MC + Fe Zn 12c) in line with EN 10025-2:2004 3.0 mm in thickness
- Application in utilisation classes 1 and 2 in line with EN 1995:2013
CE labelling as per European Technical Approval ETA-14/0274
- The respective permissible edge distances and spacings of the fasteners must be observed.
- Available work documents: Load tables and detailed installation instructions can be found on the service page www.wuerth.de/holzverbinder
CE labelling as per European Technical Approval ETA-14/0274
Base anchoring of supports, roof beams, timber frame constructions or solid wood elements in wood, steel or concrete substrates.
Suitable fasteners:
- Ring-shank nails in accordance with EN 14592: 4.0 x 40 to 100 mm
- ASSY 4.0 joist hanger screw in accordance with ETA-11/0190 or EN 14592
- Bolts in accordance with manufacturers' specifications
- Recommended anchors for fastening in concrete: W-BS; W-FAZ; W-VIZ; W-VM 250
- The respective permissible edge distances and spacings of the fasteners must be observed.
The HTA tension anchor must be fastened using a washer or solid pressure plates for HTA tension anchors
- Footplate 60x60 mm = washer 30x3 or base plate d = 10 mm
- Footplate 80x80 mm = washer 37x3
![]() | |
Width x height x depth | 60 x 340 x 60 mm |
Baseplate thickness | 9 mm |
Thickness | 3 mm |
Hole diameter in subcarrier nJ/main carrier nH | 5.1 / 17 mm |
Number of holes in subcarrier nJ + main carrier nH | 20 + 1 PCS |
Weight | 850 g |
Approval | ETA-14/0274 |
Distance between support and centre of hole | 37 mm |
Min. handle width | 60 mm |
Recommended type of anchor | W-VM250; W-FAZ |
Material | Sheet steel |
Material designation | S355MC |
Material standard | EN 10025- 2:2004 |
Surface | Zinc plated |
Overview of load capacity tables for HTA and Vplus tension anchors | |||||||||||||
Characteristic load-bearing capacity and design value of the load-bearing capacity ("short") in load case F1 for Würth tension anchor HTA and Vplus according to ETA 14/0274 | |||||||||||||
Tension anchor connection HTA and Vplus - without intermediate layer | |||||||||||||
Type | Size in mm | U-washer/base plate | KLED | Load-bearing capacity per fastener (anchor nail or joist hanger screw in mm) in kN | Load-bearing capacity steel in kN | Coefficient kt | |||||||
4x40 | 4x50 | 4x60 | 5x35 | 5x40 | 5x50 | ||||||||
Vplus | Lx90x65x3.0 | Without specification | char. | FVM,Rk = | 1,57 | 1,87 | 1,93 | 1,88 | 2,14 | 2,29 | FS,Rk = | 36,2 | 1,0 |
Short | FVM,Rd = | 1,08 | 1,30 | 1,34 | 1,30 | 1,48 | 1,59 | FS,Rd = | 29 | ||||
Lx90x65x4.0 | Without specification | char. | FVM,Rk = | 1,57 | 1,87 | 1,93 | 1,88 | 2,14 | 2,29 | FS,Rk = | 48,3 | 1,0 | |
Short | FVM,Rd = | 1,08 | 1,30 | 1,34 | 1,30 | 1,48 | 1,59 | FS,Rd = | 38,6 | ||||
HTA | Lx60x60x3.0 | U-washer 30x3 mm | char. | FVM,Rk = | 1,57 | 1,87 | 1,93 | 1,88 | 2,14 | 2,29 | FS,Rk = | 32,5 | 1,1 |
Short | FVM,Rd = | 1,08 | 1,30 | 1,34 | 1,30 | 1,48 | 1,59 | FS,Rd = | 26 | ||||
Lx60x60x3.0 | Base plate 10 mm | char. | FVM,Rk = | 1,57 | 1,87 | 1,93 | 1,88 | 2,14 | 2,29 | FS,Rk = | 45 | 1,1 | |
Short | FVM,Rd = | 1,08 | 1,30 | 1,34 | 1,30 | 1,48 | 1,59 | FS,Rd = | 36 | ||||
Lx80x80x3.0 | U-washer 37x3 mm | char. | FVM,Rk = | 1,57 | 1,87 | 1,93 | 1,88 | 2,14 | 2,29 | FS,Rk = | 60 | 1,1 | |
short | FVM,Rd = | 1,08 | 1,30 | 1,34 | 1,30 | 1,48 | 1,59 | FS,Rd = | 48 | 1,1 | |||
Tensile force in anchor bolt: FB,Ed = kt x FEd | |||||||||||||