Welcome to Würth Germany For trade customers only Contact +49 7940 15-2400

WÜTOP® Thermo Strong roofing underlay

ULAYCOV-THERMO-STRONG

Art.-no. 0681001380

EAN 4068362745300

-,--
price per selected packing unit
| Individual prices for customers after login
WÜTOP® Thermo Strong roofing underlay

Art.-no. 0681001380

-,--
price per selected packing unit
Quantity
PU
x 60 m2

Show availability in Würth shop
Exclusively for trade customers

Register now and access more than 125,000 products

Water vapour permeable, seam-bonded roofing underlay for extended applications in accordance with ZVDH [German Central Association of the Roofing Trade] regulations.

Permanently tight seams


  • The overlapping strips are welded together to form a homogeneous material using hot air or a swelling agent.

  • This process ensures watertight seams and a reliable water-bearing layer.

  • It is water vapour permeable at the same time, ensuring reliable moisture regulation within the roof structure.


Versatile application


  • When used in conjunction with the matching WÜTOP Thermo Strong system components, the underlay is suitable for various applications.

  • Suitable for installing a seam-joined underlay with integrated furring (Class 1).

  • Also suitable for installing a seam-joined underlay with nail sealing tape beneath the furring (Class 2).

  • This makes it the ideal solution for roofs with heightened requirements for rain protection and watertightness.

  • Reliable system solution for connections, penetrations and details.

  • For installation on pressure-resistant surfaces, e.g. wood formwork, engineered wood or wood fibre board.

  • Suitable as a temporary covering when used with compatible system accessories.


Roofing underlay for extended applications in accordance with ZVDH


  • Class 1 for roof pitches of 10° or more, as a watertight underlay with integrated furring.

  • Class 2 for roof pitches of 14° or more, as a rainproof underlay with nail sealing tape.
Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area

3-layer, water vapour permeable, seam-bonded roofing underlay for extended applications in accordance with ZVDH:


  • Class 1 for roof pitches of 10° or more, as a watertight underlay with integrated furring.

  • Class 2 for roof pitches of 14° or more, as a rainproof underlay with nail sealing tape.


Subject to individual contractual agreement, it can also be used for roof pitches of 5° or more. The manufacturer's specifications must be observed.



Apply to dry, clean, frost-free and pressure-resistant materials. Suitable materials include, for example, wood formwork, engineered wood board and wood fibre board.

Coating weight per m²

380 g

Length of roll

40 m

Roll width

1.5 m

Area

60 m²

Number of rolls per pallet

20 PCS

Material

Polyester fleece

Min./max. temperature resistance

-40 to 120 °C

Building material class/conditions

E - Normally inflammable / in accordance with DIN EN 13501

Air layer thickness equivalent to water-vapour diffusion/conditions

0.5 m / in accordance with EN ISO 12572

Resistance to penetration of water

W1

Resistance to tear propagation (longitudinal)

240 N

Resistance to tear propagation (transverse)

240 N

Longitudinal tensile force per 50 mm

380 N

Transverse tensile force per 50 mm

400 N

Suitable for makeshift roofing/makeshift coverage

3 Month

Building material class

E - Normally inflammable

watertightness of the seams

Passed

Design

Can be used on both sides

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information