Impact anchor W-SD WSS 1/L
DWL-(W-SD/W-WSS1/L1)-(A2K)-M6X40
Art.-no. 0905700500
EAN 4046778852515
price per selected packing unit | Individual prices for customers after login
Register now and access more than 125,000 products
Stop bits must be used (approval is subject to use of a stop bit)
Anchors and stop bits form a perfectly coordinated system. This system unit prevents installation errors and ensures attachment as stipulated in the approval.
- WSS: Pre-assembled unit (anchor, insulating part and hanger) ensures quick and easy insertion
- Acoustic insulation directly on the raw ceiling ensures long-lasting, technically sound compliance with DIN 4109
- Immediate load-bearing capacity — no waiting
- Minimal suspension height
Dimensioned in accordance with the European Technical Approval Guidelines (ETAG) for "Metal Anchors for Use in Concrete", Appendix C, measurement process C
Fire resistance (anchoring base: concrete C20/25 to C50/60): R30, R60, R90, R120: Technical Report TR 020 "Evaluation of anchorages in concrete concerning resistance to fire" (included in ETA-07/0138)
Drill the hole
Knock in anchor with setting tool until flush
Mount component
Dimensioned in accordance with the European Technical Approval Guidelines (ETAG) for "Metal Anchors for Use in Concrete", Appendix C, measurement process C
Fire resistance (anchoring base: concrete C20/25 to C50/60): R30, R60, R90, R120: Technical Report TR 020 "Evaluation of anchorages in concrete concerning resistance to fire" (included in ETA-07/0138)
Datasheets(X)
Suitable for attaching perforated strips, eyelets or wire hooks, vernier hangers etc.
Anchor diameter | 6 mm |
Anchor length (l) (l) | 61 mm |
Nominal drill-bit diameter (d 0) | 6.0 mm |
Type description | W-SD W-WSS 1/L |
Centre-to-centre distance (a) | 200 mm |
Edge clearance (a r) | 100 mm |
Minimum component thickness (d) | 100 mm |
Drill hole depth (t) | 42 mm |
Performance data | ||
Anchor diameter [mm] | WSS 1/L | |
Anchors in a redundant non-structural system of non- load-bearing systems in concrete (For all load directions) For c ≥ 150 mm for s ≥ 200 mm | Fadm [kN] ≥ C20/25 and ≤ C50/60 | 1,4 |
Admissible load when exposed to fire (R30, R60, R90, R120) see European Technical Approval ETA-07/0138 | ||
Characteristic values | ||
Spacing | scr ≥ [mm] | 200 |
Edge distance | ccr ≥ [mm] | 150 |
Drill hole depth | h1 ≥ [mm] | 42 |
Effective anchorage depth | hef ≥ [mm] | 36 |
Minimum member thickness | hmin ≥ [mm] | 80 |
Thread dia. | dthr [mm] | 6 |
Nominal drill diameter** | d0 [mm] | 6 |
Select RAL-colour code